{"id":2018,"date":"2016-04-17T16:43:23","date_gmt":"2016-04-17T14:43:23","guid":{"rendered":"http:\/\/hmg-maschinen.de\/wp\/?page_id=2018"},"modified":"2016-04-27T13:53:43","modified_gmt":"2016-04-27T11:53:43","slug":"fragen-zu-meiner-hmg-kreissaege","status":"publish","type":"page","link":"https:\/\/hmg-maschinen.de\/en\/service\/faq\/fragen-zu-meiner-hmg-kreissaege\/","title":{"rendered":"Questions for HMG saw"},"content":{"rendered":"<p><strong><span id=\"result_box\" class=\"\" lang=\"en\" tabindex=\"-1\">When electrical problems the user should try a new cable and a new outlet to 90% supply is defective (extension cords or fuses at the house)! let Please check by an expert!<\/span><\/strong><\/p>\n<p>&nbsp;<\/p>\n<table width=\"768\">\n<tbody>\n<tr>\n<td width=\"256\"><strong>problem<\/strong><\/td>\n<td width=\"256\"><strong><span id=\"result_box\" class=\"short_text\" lang=\"en\" tabindex=\"-1\">reason<\/span><\/strong><\/td>\n<td width=\"256\"><strong><span id=\"result_box\" class=\"short_text\" lang=\"en\" tabindex=\"-1\">measure<\/span><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"256\"><span id=\"result_box\" class=\"\" lang=\"en\" tabindex=\"-1\">How do I find the product number and serial number?<\/span><\/td>\n<td width=\"256\"><span id=\"result_box\" class=\"\" lang=\"en\" tabindex=\"-1\">The device has an aluminum nameplate is riveted outside<\/span><\/td>\n<td width=\"256\"><span id=\"result_box\" class=\"short_text\" lang=\"en\" tabindex=\"-1\">Type-specific <span class=\"\">data can be taken<\/span> <span class=\"\">from the<\/span> nameplate<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"256\"><span id=\"result_box\" class=\"short_text\" lang=\"en\" tabindex=\"-1\">Extension cord 4 or 5 <span class=\"\">wire<\/span><\/span><\/td>\n<td width=\"256\"><span id=\"result_box\" class=\"short_text\" lang=\"en\" tabindex=\"-1\">Extension Cable extends with 4 wheels<\/span><\/td>\n<td width=\"256\"><span id=\"result_box\" class=\"\" lang=\"en\" tabindex=\"-1\">5 cores need not be as 400V coil and no 230V is used<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"256\"><span id=\"result_box\" class=\"\" lang=\"en\" tabindex=\"-1\">My electric motor does not start or can not be turned on or makes strange noises<\/span><\/td>\n<td width=\"256\"><span id=\"result_box\" class=\"\" lang=\"en\" tabindex=\"-1\">For 95% of cases is always a broken supply line defective for <span class=\"\">machine<\/span><\/span><\/td>\n<td width=\"256\"><span id=\"result_box\" class=\"short_text\" lang=\"en\" tabindex=\"-1\">Try a new cable and connect it to another outlet<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"256\"><span id=\"result_box\" class=\"short_text\" lang=\"en\" tabindex=\"-1\">Backup is turning off<\/span><\/td>\n<td width=\"256\">\n<p><span id=\"result_box\" class=\"\" lang=\"en\" tabindex=\"-1\">a. How many backups from falling? Falling 2 backups, then switch (semiconductor) defective<\/span><\/p>\n<p>b. Potionsmeter at switches in wrong<\/td>\n<td width=\"256\">\n<p><span id=\"result_box\" class=\"\" lang=\"en\" tabindex=\"-1\">a. Replace switch<\/span><\/p>\n<p>b. (Make only slight rotary motion!) Solve rubber stopper outside of the housing and re-adjust <span class=\"\">with screwdriver<\/span> <span class=\"\">Potionsmeter<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"256\"><span id=\"result_box\" class=\"short_text\" lang=\"en\" tabindex=\"-1\">Green button does not stop<\/span><\/td>\n<td width=\"256\">\n<p><span id=\"result_box\" class=\"\" lang=\"en\" tabindex=\"-1\">a. Wrong connection black wire<\/span><\/p>\n<p>b. Thermo <span class=\"\">contact faulty<\/span><\/p>\n<p>&nbsp;<\/td>\n<td width=\"256\">\n<p>a. conductors replace the cable<\/p>\n<p>b. Switch exchange (bridging to test possible both on black!)<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">FI fuse goes<\/td>\n<td width=\"256\">\n<p>a. Moisture in the switch or motor<\/p>\n<p>b. Internal fault current<\/p>\n<p>c. defective line<\/p>\n<p>d. motor winding damage<\/p>\n<p>e. motor connected correctly<\/td>\n<td width=\"256\">checked by a qualified electrician<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Electric motor does not start or humming<\/td>\n<td width=\"256\">\n<p>a. Wrong connection<\/p>\n<p>b. fall fuses<\/p>\n<p>c. Motor protection responds<\/p>\n<p>d. Motor hums (400V Connection)<\/p>\n<p>e. Motor hums (230V Connection) button (black or red) outside of the switch box for Resat press (only 230 volt units)<\/td>\n<td width=\"256\">\n<p>a. checked lead by an expert<\/p>\n<p>b. Lead hedged too weak, possibly use larger fuses and stronger lead<\/p>\n<p>c. Lead to weak<\/p>\n<p>d. connected only 2 phases check supply<\/p>\n<p>e. key (black or red) button press outside of the switch box for Resat<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">\n<p>Electric motor running in the wrong direction (400V Connection)<\/p>\n<p>&nbsp;<\/td>\n<td width=\"256\">contact phase in the switch<\/td>\n<td width=\"256\">Turn on the machine socket 2 pole plug with a screwdriver 180 (in front of the rotational movement the slot lightly press)<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Electric motor switches off suddenly during operation<\/td>\n<td width=\"256\">\n<p>a. motor protection responds<\/p>\n<p>b. interrupted mains voltage<\/td>\n<td width=\"256\">\n<p>a. Allow the engine to cool, and check supply line, possibly missing a phase<\/p>\n<p>b. check the cables<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Switch does not work<\/td>\n<td width=\"256\">\n<p>a. Wrong connection<\/p>\n<p>b. fall fuses<\/p>\n<p>c. motor hums<\/p>\n<p>d. Motor very hot<\/td>\n<td width=\"256\">\n<p>a. checked lead by an expert<\/p>\n<p>b. Lead hedged too weak, possibly use larger fuses and stronger lead<\/p>\n<p>c. connected only 2 phases, checked lead<\/p>\n<p>d. overload protection has triggered, let the motor cool down<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">When plugging the power supply line, the line fuse trips<\/td>\n<td width=\"256\">\n<p>a. Wrong connection (phase and neutral reversed)b. Power semiconductor failure:<\/p>\n<p>c. faulty power line<\/td>\n<td width=\"256\">\n<p>a. Check the connection and switch one on security grounds for review<\/p>\n<p>b. Sent a switch for safety reasons to check and repair<\/p>\n<p>c. check cable<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">The electronic brake no longer switch off (hums continuously)<\/td>\n<td width=\"256\">Component failure on the electric brake<\/td>\n<td width=\"256\">Pull out the plug, so that the engine does not overheat. Switch for repair<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">No braking function<\/td>\n<td width=\"256\">\n<p>a. Faulty fuse on the brake circuit board of the switch.<\/p>\n<p>b. Failure of the electronic brake<\/p>\n<p>c. Potionsmeter not set<\/td>\n<td width=\"256\">\n<p>a. Replace the fuse<\/p>\n<p>b. Switch for repair<\/p>\n<p>c. (Make only slight rotary motion!) Solve rubber stopper outside of the housing and re-adjust with screwdriver Potionsmeter<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">After turning the flywheel is too fast or not braked within 10 sec.:<\/td>\n<td width=\"256\">Setting the potentiometer wrong<\/td>\n<td width=\"256\">Potentiometer with a screwdriver adjust (dial with slot sits next to the A-blanking under a rubber stopper), to the braking action and time is optimal. Do not exceed the maximum braking power<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">After switching off the engine for about 10-15 hums sec.<\/td>\n<td width=\"256\">When you turn on the table saw is the electronic brake for about 10 to max. activated 15 sec. and then off again. This is a normal operating condition and is caused by the electronic brake<\/td>\n<td width=\"256\"><\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Poor cutting performance<\/td>\n<td width=\"256\">\n<p>a. the direction of rotation of the saw blade wrong<\/p>\n<p>b. Belt loose or worn<\/p>\n<p>c. Blade is blunt<\/p>\n<p>d. Sawblade insufficient side set<\/p>\n<p>e. Blade is on the drive shaft easy<\/p>\n<p>f. Has blade with resin<\/td>\n<td width=\"256\">\n<p>a. contact phase<\/p>\n<p>b. tighten or replace belt<\/p>\n<p>c. can sharpen the saw blade<\/p>\n<p>d. checked blade of specialist<\/p>\n<p>e. retighten screw flange<\/p>\n<p>f. Circular saw blade with\u00a0deresination product clean (for example, cellulose thinner)<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Wood turns or can not be properly cut<\/td>\n<td width=\"256\">PTO speed too low<\/td>\n<td width=\"256\">Increase gas on the tractor, required speeds are indicated on the machine (various tractors achieve the required PTO speed of 540 rev \/ min only at full throttle! Check PTO speed of the tractor!<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Damaged blade<\/td>\n<td width=\"256\">\n<p>&nbsp;<\/p>\n<p>broken teeth or side impact<\/p>\n<p>&nbsp;<\/td>\n<td width=\"256\">Improper use (for example, bent timber inserted incorrectly)<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">no solution found<\/td>\n<td width=\"256\">contact workshop<\/td>\n<td width=\"256\">Turn to retailer or HMG<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>When electrical problems the user should try a new cable and a new outlet to [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":529,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/hmg-maschinen.de\/en\/wp-json\/wp\/v2\/pages\/2018"}],"collection":[{"href":"https:\/\/hmg-maschinen.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/hmg-maschinen.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/hmg-maschinen.de\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/hmg-maschinen.de\/en\/wp-json\/wp\/v2\/comments?post=2018"}],"version-history":[{"count":17,"href":"https:\/\/hmg-maschinen.de\/en\/wp-json\/wp\/v2\/pages\/2018\/revisions"}],"predecessor-version":[{"id":2682,"href":"https:\/\/hmg-maschinen.de\/en\/wp-json\/wp\/v2\/pages\/2018\/revisions\/2682"}],"up":[{"embeddable":true,"href":"https:\/\/hmg-maschinen.de\/en\/wp-json\/wp\/v2\/pages\/529"}],"wp:attachment":[{"href":"https:\/\/hmg-maschinen.de\/en\/wp-json\/wp\/v2\/media?parent=2018"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}