{"id":2394,"date":"2016-04-23T12:21:22","date_gmt":"2016-04-23T10:21:22","guid":{"rendered":"http:\/\/hmg-maschinen.de\/wp\/?page_id=2394"},"modified":"2016-07-28T16:59:19","modified_gmt":"2016-07-28T14:59:19","slug":"fragen-zum-holzspalter","status":"publish","type":"page","link":"https:\/\/hmg-maschinen.de\/en\/service\/faq\/fragen-zum-holzspalter\/","title":{"rendered":"Questions about HMG wood splitter"},"content":{"rendered":"<p><strong><span id=\"result_box\" class=\"\" lang=\"en\" tabindex=\"-1\">When electrical problems the user should try a new cable and a new outlet to 90% supply is defective (extension cords or fuses at the house)! let Please check by an expert!<\/span><\/strong><\/p>\n<p>&nbsp;<\/p>\n<table width=\"768\">\n<tbody>\n<tr>\n<td width=\"256\"><strong>problem<\/strong><\/td>\n<td width=\"256\"><strong><span id=\"result_box\" class=\"short_text\" lang=\"en\" tabindex=\"-1\">reason<\/span><\/strong><\/td>\n<td width=\"256\"><strong><span id=\"result_box\" class=\"short_text\" lang=\"en\" tabindex=\"-1\">measure<\/span><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"256\"><span id=\"result_box\" class=\"\" lang=\"en\" tabindex=\"-1\">How do I find the product number and serial number<span class=\"\">?<\/span><\/span><\/td>\n<td width=\"256\"><span id=\"result_box\" class=\"\" lang=\"en\" tabindex=\"-1\">The device has an aluminum nameplate is riveted outside<\/span><\/td>\n<td width=\"256\"><span id=\"result_box\" class=\"short_text\" lang=\"en\" tabindex=\"-1\">Type-specific data can be taken from the nameplate<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"256\"><span id=\"result_box\" class=\"short_text\" lang=\"en\" tabindex=\"-1\">Extension cord 4 or <span class=\"\">5<\/span> <span class=\"\">wire<\/span><\/span><\/td>\n<td width=\"256\"><span id=\"result_box\" class=\"short_text\" lang=\"en\" tabindex=\"-1\">Extension Cable extends with 4 wheels<\/span><\/td>\n<td width=\"256\"><span id=\"result_box\" class=\"\" lang=\"en\" tabindex=\"-1\">5 cores need not be as 400V coil and no 230V is used<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"256\"><span id=\"result_box\" class=\"\" lang=\"en\" tabindex=\"-1\">My electric motor does not start or can not be turned on or makes strange noises<\/span><\/td>\n<td width=\"256\"><span id=\"result_box\" class=\"\" lang=\"en\" tabindex=\"-1\">For 95% of cases is always a broken supply line defective for machine<\/span><\/td>\n<td width=\"256\"><span id=\"result_box\" class=\"short_text\" lang=\"en\" tabindex=\"-1\">Try a new cable and connect it to <span class=\"\">another outlet<\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"256\"><span id=\"result_box\" class=\"short_text\" lang=\"en\" tabindex=\"-1\">Backup is turning off<\/span><\/td>\n<td width=\"256\"><span id=\"result_box\" class=\"\" lang=\"en\" tabindex=\"-1\">How many backups from falling? Falling 2 backups, then switch (semiconductor) defective.<\/span><\/td>\n<td width=\"256\"><span id=\"result_box\" class=\"short_text\" lang=\"en\" tabindex=\"-1\">Replace switch<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"256\"><span id=\"result_box\" class=\"short_text\" lang=\"en\" tabindex=\"-1\">Green button <span class=\"\">does not stop<\/span><\/span><\/td>\n<td width=\"256\">\n<p>&nbsp;<\/p>\n<p><span id=\"result_box\" class=\"\" lang=\"en\" tabindex=\"-1\">a. Wrong connection black wire<\/span><\/p>\n<p>b. Thermo contact faulty<\/p>\n<p>&nbsp;<\/td>\n<td width=\"256\">\n<p><span id=\"result_box\" class=\"\" lang=\"en\" tabindex=\"-1\">a. conductors replace the cable<\/span><\/p>\n<p>b. Switch exchange (bridging to test possible both on black<span class=\"\">!<\/span><span class=\"\">)<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"256\"><span id=\"result_box\" class=\"short_text\" lang=\"en\" tabindex=\"-1\">FI <span class=\"\">fuse<\/span> <span class=\"\">goes<\/span><\/span><\/td>\n<td width=\"256\">\n<p><span id=\"result_box\" class=\"\" lang=\"en\" tabindex=\"-1\">a. Moisture in the switch or motor<\/span><\/p>\n<p>b. Internal fault current<\/p>\n<p>c<span class=\"\">.<\/span> <span class=\"\">defective<\/span> <span class=\"\">line<\/span><\/p>\n<p>d. motor winding <span class=\"\">damage<\/span><\/p>\n<p>e. motor connected correctly<\/td>\n<td width=\"256\"><span id=\"result_box\" class=\"short_text\" lang=\"en\" tabindex=\"-1\">checked by <span class=\"\">a qualified electrician<\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"256\"><span id=\"result_box\" class=\"short_text\" lang=\"en\" tabindex=\"-1\">Electric motor does not start or <span class=\"\">humming<\/span><\/span><\/td>\n<td width=\"256\"><span id=\"result_box\" class=\"\" lang=\"en\" tabindex=\"-1\">a. Wrong connection<br \/>\n<\/span><span id=\"result_box\" class=\"\" lang=\"en\" tabindex=\"-1\">b. fall fuses<br \/>\n<\/span><\/p>\n<p><span id=\"result_box\" class=\"\" lang=\"en\" tabindex=\"-1\">c. Motor <span class=\"\">protection responds<\/span><br \/>\n<\/span><\/p>\n<p><span id=\"result_box\" class=\"\" lang=\"en\" tabindex=\"-1\">d. Motor hums (400V <span class=\"\">Connection<\/span>)<br \/>\n<\/span><\/p>\n<p><span id=\"result_box\" class=\"\" lang=\"en\" tabindex=\"-1\">e. Motor hums (230V <span class=\"\">Connection<\/span>) button (<span class=\"\">black or red<\/span>) outside of the switch box for Resat press (only 230 volt units)<\/span><\/td>\n<td width=\"256\">\n<p>a. checked lead by an expert<\/p>\n<p>b. Lead hedged too weak, possibly use larger fuses and stronger lead<\/p>\n<p>c. Lead to weak<\/p>\n<p>d. connected only 2 phases check supply<\/p>\n<p>e. key (black or red) button press outside of the switch box for Resat<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">\n<p>Electric motor running in the wrong direction (400V Connection)<\/p>\n<p>&nbsp;<\/td>\n<td width=\"256\">contact phase in the switch<\/td>\n<td width=\"256\">Turn on the machine socket 2 pole plug with a screwdriver 180 (in front of the rotational movement the slot lightly press)<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Electric motor switches off suddenly during operation<\/td>\n<td width=\"256\">\n<p>a. motor protection responds<\/p>\n<p>b. interrupted mains voltage<\/td>\n<td width=\"256\">\n<p>a. Allow the engine to cool, and check supply line, possibly missing a phase<\/p>\n<p>b. check the cables<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Switch does not work<\/td>\n<td width=\"256\">\n<p>a. Wrong connection<\/p>\n<p>b. fall fuses<\/p>\n<p>c. motor hums<\/p>\n<p>d. Motor very hot<\/td>\n<td width=\"256\">\n<p>a. checked lead by an expertb. Lead hedged too weak, possibly use larger fuses and stronger lead<\/p>\n<p>c. connected only 2 phases, checked lead<\/p>\n<p>d. overload protection has triggered, let the motor cool down<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Splitting blade does not extend<\/td>\n<td width=\"256\">\n<p>a. the motor rotation direction wrong<\/p>\n<p>b. Wrong direction of rotation of the PTO<\/p>\n<p>c. Not enough oil in the oil tank<\/p>\n<p>d. adjusted screw the adjustment linkage of the two-hand control<\/p>\n<p>e. Stroke splitting blade activated<\/td>\n<td width=\"256\">\n<p>a. Phase contact in the switch<\/p>\n<p>b. change direction of rotation<\/p>\n<p>c. Check the oil level<\/p>\n<p>d. must be set in the factory or by dealer<\/p>\n<p>e. Stroke solve splitting knife<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Splitting blade does not retract<\/td>\n<td width=\"256\">\n<p>a. see Troubleshooting<\/p>\n<p>b. dissolved pin of the piston rod of the cylinder<\/p>\n<p>c. defective seals the cylinder<\/p>\n<p>d. Stroke splitting blade activated<\/td>\n<td width=\"256\">\n<p>a. &#8220;Splitting blade does not extendb. Mast with welded knife would go upstairs for pulling<\/p>\n<p>c. Seals the cylinder renew (Check cause, probably switched device in neutral position!)<\/p>\n<p>d. Stroke solve splitting knife<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Splitting blade does not force<\/td>\n<td width=\"256\">\n<p>a. Not enough oil in the oil tank<\/p>\n<p>b. damaged cylinder seal kit<\/p>\n<p>c. worn hydraulic pump<\/p>\n<p>d. adjusted control valve or two-hand control<\/td>\n<td width=\"256\">\n<p>a. Check the oil level<\/p>\n<p>b. Dichtungssatz renew (Check cause, probably switched device in neutral position!)<\/p>\n<p>c. Replace the pump<\/p>\n<p>d. can be set in the factory or by dealer<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">blocked splitting knife<\/td>\n<td width=\"256\">Wood too hasty<\/td>\n<td width=\"256\">turn wood<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Splitting blade moves jerkily<\/td>\n<td width=\"256\">Not enough oil in the oil tank<\/td>\n<td width=\"256\">Check the oil level<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Lowered cylinder moves not in working position (series HSP 10M-24M)<\/td>\n<td width=\"256\">Two-hand control is placed and fixed on NEUTRAL POSITION<\/td>\n<td width=\"256\">Loosen travel stop after switching on the drive and slowly drive cylinder in the working position<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Drive dies shortly after takeoff from always (as tractor dies when switching the PTO from) (Series HSP 10M-24M)<\/td>\n<td width=\"256\">Cylinder is in transport position and two-hand control is not set to NEUTRAL POSITION<\/td>\n<td width=\"256\">Enable Stroke while pressing a two-hand control<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">Hydraulic lines are very hot<\/td>\n<td width=\"256\">\n<p>a. Not enough oil in the oil tank<\/p>\n<p>b. PTO speed too high<\/p>\n<p>c. damaged hydraulic pump<\/td>\n<td width=\"256\">\n<p>a. Check the oil level<\/p>\n<p>b. comply with speed (the maximum speed is given another machine!)<\/p>\n<p>c. Replace the pump<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">leaking hydraulic cylinders<\/td>\n<td width=\"256\">worn sealing sleeve or piston rod<\/td>\n<td width=\"256\">renew<\/td>\n<\/tr>\n<tr>\n<td width=\"256\">no solution found<\/td>\n<td width=\"256\">contact workshop<\/td>\n<td width=\"256\">Turn to retailer or HMG<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>When electrical problems the user should try a new cable and a new outlet to [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":529,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/hmg-maschinen.de\/en\/wp-json\/wp\/v2\/pages\/2394"}],"collection":[{"href":"https:\/\/hmg-maschinen.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/hmg-maschinen.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/hmg-maschinen.de\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/hmg-maschinen.de\/en\/wp-json\/wp\/v2\/comments?post=2394"}],"version-history":[{"count":14,"href":"https:\/\/hmg-maschinen.de\/en\/wp-json\/wp\/v2\/pages\/2394\/revisions"}],"predecessor-version":[{"id":3128,"href":"https:\/\/hmg-maschinen.de\/en\/wp-json\/wp\/v2\/pages\/2394\/revisions\/3128"}],"up":[{"embeddable":true,"href":"https:\/\/hmg-maschinen.de\/en\/wp-json\/wp\/v2\/pages\/529"}],"wp:attachment":[{"href":"https:\/\/hmg-maschinen.de\/en\/wp-json\/wp\/v2\/media?parent=2394"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}